Specifications Table

Model KJLC ACG
Technology Capacitance Manometer
Full Scale
Range
0.10  mbar
0.10  Torr
0.25  Torr
0.50  Torr
1.00  mbar
1.00  Torr
2.00  Torr
5.00  Torr
10.0  Torr
20.0  Torr
50.0  Torr
100  Torr
200  Torr
500  Torr
1000  Torr
1100  mbar
Temperature Operating
50.0 ºC
122 ºF

Storage
65.0 ºC
150 ºF

Bakeout
≤ 110 ºC
≤ 230 ºF

Materials Exposed to Vacuum Aluminum oxide ceramic Stainless steel (AISI 316L)
Connectors 15 Pin Sub D Male
Typical
Accuracy
±0.25% of reading
±0.25% of reading (0.5 and 0.25 options)
±0.2% of reading (≥1 Torr)
±0.5% of reading (0.1 option)
Accuracy
Range
0.05 to 1%
Display
Type
N/A
Set-Point
Relays
2
Relay
Response
≤ 30 VDC
Analog
Output
0 to 10 VDC
Recommended
Mounting Orientation
Any except for upside down
Input
Power
14 to 30 VDC
≤ 1 W
Communications
(Standard)
Analog
RS232
Compliance
and Standards
CE
RoHS
UL
CSA
EN
SEMI
Integrated
Electronics
Yes
X CLOSE
Suggested Measure & Control Pressure
For a guide to help spec in the correct Full Scale (F.S.) range for a capacitance manometer, please click here.
Product Downloads
Product Downloads
Below is a list of available file downloads for this product.
KJLC ACG Series Manual
RS232C Communication Manual
KJLC ACG Diaphragm Gauge Datasheet
Gauge Selection Guide
With a variety of gauges to choose from, the Gauge Selection Guide is designed to help you find the right gauge to meet your vacuum requirements.
Gauges FAQ
Click here for answers to some of the most common questions we are asked.
Contact Us
Contact Us
To contact someone directly, please click here, or call +1 412 387 9200 to get in contact with your dedicated sales team.

Start Your Configuration

1. Series: ACG 25 Deg Ambient [ACG-]
2. Measurement Range:
3. Unit:
4. Flange:
5. Pressure Control Option:
 
Notes:
  • Due to export compliance rules, product may not be available for sale to all regions.
  • Please reference the ordering table below for units that we generally have in stock in one of our global warehouses.

Got VacuCADSM?
VacuCAD is a free library containing thousands of 2D CAD drawings (in DXF format) and 3D Models (in STP format) for many of our standard vacuum components and chambers. Please Log in

Ordering Table

X CLOSE
Description Technology Display Type Set-Point Relays Connector Type Flange Communications (Standard) Full Scale Range
VacuCADSM
Part Number Price In Stock Add To Cart Accessories
Description Technology Display Type Set-Point Relays Connector Type Flange Communications (Standard) Full Scale Range
VacuCADSM
Part Number Price In Stock Add To Cart Accessories
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1100 MBAR, QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 1100 mbar
N/A
ACG-AM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1000 TORR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 1000 Torr
N/A
ACG-BT-1-1
P.O.R. In Stock
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 10 TORR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 10 Torr
N/A
ACG-HT-1-1
P.O.R. In Stock
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 MBAR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 1 mbar
N/A
ACG-KM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 MBAR F.S., 1.33CF-R (DN16CF-R) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male DN16CF Analog,RS232 1 mbar
N/A
ACG-KM-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 TORR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 1 Torr
N/A
ACG-KT-1-1
P.O.R. In Stock
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 TORR F.S., QF16 (DN16KF) FLANGE, PRESSURE CONTROL Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 1 Torr
N/A
ACG-KT-1-2
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 MBAR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 0.1 mbar
N/A
ACG-NM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 MBAR F.S., 1.33CF-R (DN16CF-R) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male DN16CF Analog,RS232 0.1 mbar
N/A
ACG-NM-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 TORR F.S., QF16 (DN16KF) FLANGE Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 0.1 Torr
N/A
ACG-NT-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 TORR F.S., QF16 (DN16KF) FLANGE, PRESSURE CONTROL Capacitance Manometer N/A 2 15 Pin Sub D Male KF16 Analog,RS232 0.1 Torr
N/A
ACG-NT-1-2
P.O.R. Contact KJLC for Availability
CloseX