Specifications Table

Model KJLC ACG
Technology Capacitance Manometer
Full Scale
Range
0.10  Torr
0.10  mbar
0.25  Torr
0.50  Torr
1.00  mbar
1.00  Torr
2.00  Torr
5.00  Torr
10.0  Torr
20.0  Torr
50.0  Torr
100  Torr
200  Torr
500  Torr
1000  Torr
1100  mbar
Temperature Operating
50.0 ºC
122 ºF

Storage
65.0 ºC
150 ºF

Bakeout
≤ 110 ºC
≤ 230 ºF

Temperature
Compensation, ºC
Ambient
Materials Exposed to Vacuum Aluminum oxide ceramic Stainless steel (AISI 316L)
Connectors 15 Pin Sub D Male
Typical
Accuracy
±0.2% of reading (≥1 Torr)
±0.5% of reading (0.1 option)
±0.25% of reading
±0.25% of reading (0.5 and 0.25 options)
Accuracy
Range
0.05 to 1%
Display
Type
N/A
Set-Point
Relays
2
Relay
Response
≤ 30 VDC
Analog
Output
0 to 10 VDC
Recommended
Mounting Orientation
Any except for upside down
Input
Power
14 to 30 VDC
≤ 1 W
Communications
(Standard)
Analog
RS232
Communications
(Optional)
N/A
Compliance
and Standards
CE
RoHS
UL
CSA
EN
SEMI
Integrated
Electronics
Yes
X CLOSE
Suggested Measure & Control Pressure
For a guide to help spec in the correct Full Scale (F.S.) range for a capacitance manometer, please click here.
VacuCAD Downloads
VacuCAD Downloads
Please login to your Viewport account to access VacuCAD files for this product.
Product Downloads
Product Downloads
Below is a list of available file downloads for this product.
KJLC ACG Series Manual
RS232C Communication Manual
KJLC ACG Diaphragm Gauge Datasheet
Product Cross-Reference Inquiry
Click here to fill out our form and KJLC can cross-reference your vacuum product and suggest either a replacement or equivalent product.
Gauge Selection Guide
With a variety of gauges to choose from, the Gauge Selection Guide is designed to help you find the right gauge to meet your vacuum requirements.
Gauges FAQ
Click here for answers to some of the most common questions we are asked.
Contact Us
Contact Us
To contact someone directly, please click here, or call +1 412 387 9200 to get in contact with your dedicated sales team.

Start Your Configuration

1. Series: ACG 25 Deg Ambient [ACG-]
2. Measurement Range:
3. Unit:
4. Flange:
5. Pressure Control Option:
 
Notes:
  • Due to export compliance rules, product may not be available for sale to all regions.
  • Please reference the ordering table below for units that we generally have in stock in one of our global warehouses.

Got VacuCADSM?
VacuCAD is a free library containing thousands of 2D CAD drawings (in DXF format) and 3D Models (in STP format) for many of our standard vacuum components and chambers. Please Log in

Ordering Table

X CLOSE
Description Flange Full Scale Range Temperature Compensation, ºC
VacuCADSM
Part Number Price In Stock Add To Cart Accessories
Description Flange Full Scale Range Temperature Compensation, ºC
VacuCADSM
Part Number Price In Stock Add To Cart Accessories
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1100 MBAR, QF16 (DN16KF) FLANGE KF16 1100 mbar Ambient
(please log in)
ACG-AM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1000 TORR F.S., QF16 (DN16KF) FLANGE KF16 1000 Torr Ambient
(please log in)
ACG-BT-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 100 TORR F.S., QF16 (DN16KF) FLANGE KF16 100 Torr Ambient
N/A
ACG-ET-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 100 TORR F.S., 1.33CF-R (DN16CF-R) FLANGE DN16CF 100 Torr Ambient
N/A
ACG-ET-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 10 TORR F.S., QF16 (DN16KF) FLANGE KF16 10 Torr Ambient
(please log in)
ACG-HT-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 10 TORR F.S., 1.33CF-R (DN16CF-R) FLANGE DN16CF 10 Torr Ambient
N/A
ACG-HT-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 MBAR F.S., QF16 (DN16KF) FLANGE KF16 1 mbar Ambient
(please log in)
ACG-KM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 MBAR F.S., 1.33CF-R (DN16CF-R) FLANGE DN16CF 1 mbar Ambient
(please log in)
ACG-KM-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 TORR F.S., QF16 (DN16KF) FLANGE KF16 1 Torr Ambient
(please log in)
ACG-KT-1-1
P.O.R. In Stock
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, 1 TORR F.S., QF16 (DN16KF) FLANGE, PRESSURE CONTROL KF16 1 Torr Ambient
(please log in)
ACG-KT-1-2
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 MBAR F.S., QF16 (DN16KF) FLANGE KF16 0.1 mbar Ambient
(please log in)
ACG-NM-1-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 MBAR F.S., 1.33CF-R (DN16CF-R) FLANGE DN16CF 0.1 mbar Ambient
(please log in)
ACG-NM-2-1
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 TORR F.S., QF16 (DN16KF) FLANGE KF16 0.1 Torr Ambient
(please log in)
ACG-NT-1-1
P.O.R. In Stock
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 TORR F.S., QF16 (DN16KF) FLANGE, PRESSURE CONTROL KF16 0.1 Torr Ambient
(please log in)
ACG-NT-1-2
P.O.R. Contact KJLC for Availability
EUDF, CAPACITANCE MANOMETER, KJLC ACG, AMBIENT, .1 TORR F.S., 1.33CF-R (DN16CF-R) FLANGE DN16CF 0.1 Torr Ambient
N/A
ACG-NT-2-1
P.O.R. Contact KJLC for Availability
CloseX
X CLOSE
Contact Us - KJLC® ACG Ambient Series Capacitance Manometers