Galden® PFPE as a Replacement for 3M™ Fluorinert™ & Novec™ Fluids

Drop-in replacements for 3M™ Fluorinert™ and Novec™ fluids that meet or exceed their chemical and thermal properties

Drop-in replacements for 3M™ Fluorinert™ and Novec™ fluids that meet or exceed their chemical and thermal properties

The discontinuation of 3M Fluorinert™ and Novec™ fluids have created an urgent need for reliable long-term replacement dielectric fluids across semiconductor manufacturing, electronics testing, immersion cooling, among other industrial heat transfer applications. Sysenqo's Galden® PFPE fluid portfolio has emerged as a leading alternative, providing exceptional dielectric properties, outstanding chemical and thermal stability, and a wide range of fluid grades capable of supporting the applications previously served by Fluorinert™ and Novec™. The Galden® product line has already been qualified by and specified in with some of the largest OEMs and end users in industry, has NSF approval for food contact, and is FM standard 6930 compliant.

Find the Right Replacement Fluid for Your Application

3M™ Heat
Transfer Fluid
Recommended Galden®
Replacement
Application Product
Comparison
Fluorinert™ 87 Galden® HT 55 Immersion cooling, leak detection, thermal shock testing
Property Fluorinert™ 87 Galden® HT 55
Vapor Pressure (Torr) 610 225
Pour Point (°C) -101 -110
Boiling Point (°C) 30 55
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 9.5 16
Molecular Weight (g/mol) 290 340
Heat of Vaporization @ BP (Cal/g) 24 22
Kinematic Viscosity (cSt) 0.4 0.45
Thermal Conductivity (W/m•K) 0.056 0.065
Ambient Density (g/cm3) 1.63 1.65
Volume Resistivity (Ohm cm) 5.6 × 1015 1 × 1012
Dielectric Strength (kV) 42 40
Nominal Dielectric Constant* 1.72 1.86
Fluorinert™ 72 Galden® HT 55 Electronics cooling, immersion cooling, burn-in testing, reliability testing, leak testing
Property Fluorinert™ 72 Galden® HT 55
Vapor Pressure (Torr) 232 225
Pour Point (°C) -90 -110
Boiling Point (°C) 56 55
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 10 16
Molecular Weight (g/mol) 338 340
Heat of Vaporization @ BP (Cal/g) 21 22
Kinematic Viscosity (cSt) 0.38 0.45
Thermal Conductivity (W/m•K) 0.057 0.065
Ambient Density (g/cm3) 1.68 1.65
Volume Resistivity (Ohm cm) 1 × 1015 1 × 1012
Dielectric Strength (kV) 38 40
Nominal Dielectric Constant* 1.75 1.86
Fluorinert™ 84 Galden® HT 70 Environmental stress screening, reliability testing, immersion cooling, leak testing
Property Fluorinert™ 84 Galden® HT 70
Vapor Pressure (Torr) 79 141
Pour Point (°C) -95 -115
Boiling Point (°C) 80 70
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 13 14
Molecular Weight (g/mol) 388 410
Heat of Vaporization @ BP (Cal/g) 19 17
Kinematic Viscosity (cSt) 0.55 0.5
Thermal Conductivity (W/m•K) 0.06 0.065
Ambient Density (g/cm3) 1.73 1.68
Volume Resistivity (Ohm cm) 1 × 1015 1 × 1015
Dielectric Strength (kV) 42 40
Nominal Dielectric Constant* 1.81 1.88
Fluorinert™ 77 Galden® HT 110 Electronics cooling, heat-transfer loops, power-device cooling
Property Fluorinert™ 77 Galden® HT 110
Vapor Pressure (Torr) 42 17
Pour Point (°C) -95 -100
Boiling Point (°C) 97 110
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 15 16
Molecular Weight (g/mol) 415 580
Heat of Vaporization @ BP (Cal/g) 20 17
Kinematic Viscosity (cSt) 0.8 0.77
Thermal Conductivity (W/m•K) 0.063 0.065
Ambient Density (g/cm3) 1.78 1.71
Volume Resistivity (Ohm cm) 1.9 × 1015 1.5 × 1015
Dielectric Strength (kV) 40 40
Nominal Dielectric Constant* 1.86 1.92
Fluorinert™ 3283 Galden® HT 135 High temperature heat transfer where dielectric properties are required
Property Fluorinert™ 3283 Galden® HT 135
Vapor Pressure (Torr) 11 5.8
Pour Point (°C) -65 -100
Boiling Point (°C) 128 135
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 14.6 17
Molecular Weight (g/mol) 521 610
Heat of Vaporization @ BP (Cal/g) 18 16
Kinematic Viscosity (cSt) 0.75 1
Thermal Conductivity (W/m•K) 0.066 0.065
Ambient Density (g/cm3) 1.82 1.72
Volume Resistivity (Ohm cm) 5 × 1015 1.5 × 1015
Dielectric Strength (kV) 43 40
Nominal Dielectric Constant* 1.89 1.92
Fluorinert™ 40 Galden® HT 170 High temperature heat transfer fluid
Property Fluorinert™ 40 Galden® HT 170
Vapor Pressure (Torr) 3 0.8
Pour Point (°C) -50 -97
Boiling Point (°C) 165 170
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 16 18
Molecular Weight (g/mol) 650 760
Heat of Vaporization @ BP (Cal/g) 17 16
Kinematic Viscosity (cSt) 2.2 1.8
Thermal Conductivity (W/m•K) 0.066 0.065
Ambient Density (g/cm3) 1.87 1.77
Volume Resistivity (Ohm cm) 4 × 1015 1.5 × 1015
Dielectric Strength (kV) 46 40
Nominal Dielectric Constant* 1.89 1.94
Fluorinert™ 43 Galden® HT 170 High temperature heat transfer fluid
Property Fluorinert™ 43 Galden® HT 170
Vapor Pressure (Torr) 1.4 0.8
Pour Point (°C) -50 -97
Boiling Point (°C) 174 170
Specific Heat (Cal/g•°C) 0.263 0.23
Surface Tension (dyne/cm) 16 18
Molecular Weight (g/mol) 670 760
Heat of Vaporization @ BP (Cal/g) 16.7 16
Kinematic Viscosity (cSt) 2.5 1.8
Thermal Conductivity (W/m•K) 0.065 0.065
Ambient Density (g/cm3) 1.86 1.77
Volume Resistivity (Ohm cm) 3.4 × 1015 1.5 × 1015
Dielectric Strength (kV) 42 40
Nominal Dielectric Constant* 1.9 1.94
Fluorinert™ 70 Galden® HT 200 Extreme temperature heat transfer fluid, calibration baths, specialty thermal management
Property Fluorinert™ 70 Galden® HT 200
Vapor Pressure (Torr) <0.1 0.2
Pour Point (°C) -25 -85
Boiling Point (°C) 215 200
Specific Heat (Cal/g•°C) 0.25 0.23
Surface Tension (dyne/cm) 18 19
Molecular Weight (g/mol) 820 870
Heat of Vaporization @ BP (Cal/g) 16 15
Kinematic Viscosity (cSt) 14 2.4
Thermal Conductivity (W/m•K) 0.07 0.065
Ambient Density (g/cm3) 1.94 1.79
Volume Resistivity (Ohm cm) 2.3 × 1015 6 × 1015
Dielectric Strength (kV) 40 40
Nominal Dielectric Constant* 1.98 1.94
Novec™ 7100 Galden® HT 70 Precision cleaning, vapor degreasing, carrier solvent, moderate temperature heat transfer
Property Novec™ 7100 Galden® HT 70
Vapor Pressure (Torr) 202 141
Pour Point (°C) -135 -115
Boiling Point (°C) 61 70
Specific Heat (Cal/g•°C) 0.28 0.23
Surface Tension (dyne/cm) 13.6 14
Molecular Weight (g/mol) 250 410
Heat of Vaporization @ BP (Cal/g) 27 17
Kinematic Viscosity (cSt) 0.38 0.5
Thermal Conductivity (W/m•K) 0.069 0.065
Ambient Density (g/cm3) 1.52 1.68
Volume Resistivity (Ohm cm) Not reported 1 × 1015
Dielectric Strength (kV) >25 40
Nominal Dielectric Constant* 7.4 1.88
Novec™ 7200 Galden® HT 70 Dielectric cooling, semiconductor equipment cooling, laboratory temperature controllers
Property Novec™ 7200 Galden® HT 70
Vapor Pressure (Torr) 109 141
Pour Point (°C) -138 -115
Boiling Point (°C) 76 70
Specific Heat (Cal/g•°C) 0.29 0.23
Surface Tension (dyne/cm) 13.6 14
Molecular Weight (g/mol) 264 410
Heat of Vaporization @ BP (Cal/g) 30 17
Kinematic Viscosity (cSt) 0.61 0.5
Thermal Conductivity (W/m•K) 0.069 0.065
Ambient Density (g/cm3) 1.43 1.68
Volume Resistivity (Ohm cm) Not reported 1 × 1015
Dielectric Strength (kV) >25 40
Nominal Dielectric Constant* 7.3 1.88
Novec™ 7500 Galden® HT 135 High temperature heat transfer, thermal management loops
Property Novec™ 7500 Galden® HT 135
Vapor Pressure (Torr) 6 5.8
Pour Point (°C) -100 -100
Boiling Point (°C) 128 135
Specific Heat (Cal/g•°C) 0.27 0.23
Surface Tension (dyne/cm) 16.2 17
Molecular Weight (g/mol) 414 610
Heat of Vaporization @ BP (Cal/g) 21.1 16
Kinematic Viscosity (cSt) 0.77 1
Thermal Conductivity (W/m•K) 0.065 0.065
Ambient Density (g/cm3) 1.61 1.72
Volume Resistivity (Ohm cm) 2.2 × 108 1.5 × 1015
Dielectric Strength (kV) 35 40
Nominal Dielectric Constant* 5.8 1.92

Dielectric constant values are nominal room-temperature values reported by the manufacturers. Because dielectric constant is frequency-dependent and test frequencies are not always reported consistently, values should be used for general comparison purposes only.

The chemical and physical properties of Fluorinert™ and Novec™ products are taken directly from 3M™ technical data sheets. KJLC cannot confirm or guarantee their accuracy.

Galden Heat Transfer Fluids

Explore Galden® Heat Transfer Fluids from KJLC

KJLC offers Galden® HT heat transfer fluids in a range of grades for demanding thermal management applications. Explore the product line to review fluid properties, compare specifications, and view ordering options for the grade that meets your application requirements.

View Galden® Grades & Ordering Options

Why Partner with KJLC

The transition away from legacy fluorinated fluids involves more than just identifying a suitable replacement. It requires establishing long-term supply chain solutions, access to knowledgeable technical support, and a parter who understands and values the critical demands of your application. The Kurt J. Lesker Company combines decades of industry experience with a dedicated support staff to assist customers in all aspects of fluid selection, from qualification to procurement strategies.

  • Technical Expertise: Our team is highly knowledgeable in fluorinated fluids and their application in high-tech industries. We will guide you through the transition process to ensure the perfect solution.
  • Long-term Supply Chain Confidence: KJLC offers reliable sourcing strategies to ensure on-time delivery of your ongoing fluid requirements.
  • Comprehensive Customer Support: From product selection to procurement strategies and troubleshooting, KJLC is committed to supporting your long-term success.

Frequently Asked Questions

Syensqo's Galden® PFPE fluids are an ideal replacement for the 3M™ Fluorinert™ fluid line. The Galden® product portfolio can be used as a drop-in replacement that meets or exceeds many of the chemical and thermal properties of the 3M™ fluids. Galden® products have been qualified by and specified in with some of the largest OEMs and end users in semiconductor manufacturing, EV battery cooling, aerospace, data center cooling, among other industries. The Kurt J. Lesker Company is a verified distributor of Galden® products.

Syensqo's Galden® PFPE fluids are an ideal replacement for the 3M™ Novec™ fluid line. The Galden® product portfolio can be used as a drop-in replacement that meets or exceeds many of the chemical and thermal properties of the 3M™ fluids. Galden® products have been qualified by and specified in with some of the largest OEMs and end users in semiconductor manufacturing, EV battery cooling, aerospace, data center cooling, among other industries. The Kurt J. Lesker Company is a verified distributor of Galden® products.

Yes, all Galden® products can be used as a drop-in replacement for the corresponding Fluorinert™ or Novec™ product. Whether formal requalification is required depends on the regulatory and compliance needs of your specific application.

With 3M™ discontinuing its fluorinated fluid lines, users require a long-term replacement that maintains the performance and reliability demanded by critical applications. Galden® PFPE fluids offer exceptional chemical and thermal stability, excellent dielectric properties, and a proven successful history in semiconductor manufacturing, electronics testing, aerospace, immersion cooling, among other industrial heat transfer systems. With replacement options available for many of the discontinued 3M™ products, Galden® provides a practical path forward for long-term availability and dependable performance.

The fluid is typically specified in the equipment documentation, indicated in process specification sheets, or even on a refilling container label. If you have the product number, our Fluid Replacement Guide can help identify the appropriate Galden® replacement. If you have the application parameters, but not the product number, our specialists can assist you in determining the appropriate fluid.

3M™ discontinued the Fluorinert™ and Novec™ product lines as part of a broader exit from fluorochemical manufacturing. The decision was driven in-part by legal and regulatory pressure surrounding per- and polyfluoroalkyl substances (PFAS), not to any technical issues with the products. Sysenqo's Galden® PFPE fluid portfolio can be used as a drop-in replacement for the 3M™ discontinued products.

Galden® PFPE is a family of inert, high-performance, fluorinated fluids that offer superior dielectric properties, exceptional chemical stability, and operate at temperatures ranging from -70°C to 290°C (-94°F to 554°F).

TALK TO A SPECIALIST

Contact one of our experts, our team is ready to help you find the right solution for your application.

Contact Us - Galden PFPE as a replacement for 3M Fluorinert and Novec Fluids